    Electrical Wiring in an Apartment: Planning and Safety

    Electrical Wiring in an Apartment: Planning and Safety

    Apartment electrical wiring is one of those trades that disappears the moment the walls close — which is exactly why it is where corners get cut. The result is either a breaker that trips every time the kettle goes on or, at worst, a fire. This guide covers how apartment electrical wiring should be planned.

    02

    Load first, circuits second

    Planning starts with a list of appliances: hob, oven, dishwasher, washing machine, water heater, air conditioning. Each has a rating, and the total determines whether the incoming supply is adequate. In older Georgian buildings the supply is often 3–5 kW, which is below what a modern flat needs.

    The five stages of designing an apartment electrical installation
    From load calculation to testing
    03

    Why everything cannot share one circuit

    A flat wired onto a single breaker creates two problems. First, when it trips the whole apartment goes dark and you cannot tell where the fault is. Second and more serious: a cable sized for 16 amps ends up carrying 25, runs warm, and its insulation degrades over time.

    The correct approach: lighting on its own, sockets grouped by room, and every heavy appliance on a dedicated circuit with its own breaker.

    04

    Cable sizing

    Table matching cable size and breaker rating by circuit type
    Cable and breaker have to match

    The governing principle: the breaker protects the cable, not the appliance. A breaker must never be rated above the current-carrying capacity of the cable it feeds. Fitting a 25 A breaker to 2.5 mm² cable is precisely the mistake that renders the protection meaningless.

    05

    The safety minimum

    Six minimum electrical safety requirements for apartment wiring
    Six requirements with no room for compromise
    • 30 mA RCD on every wet-zone circuit
    • A dedicated circuit for each heavy appliance
    • Earthing at every socket, not only in wet areas
    • Spare capacity — at least 20% free ways in the board
    • Cable runs vertical and horizontal only, never diagonal
    • Photographic record of every run before the walls are closed

    Diagonal runs are particularly dangerous: with a vertical-and-horizontal layout you can reason about where a cable is before drilling. With diagonals you cannot.

    06

    How many points are enough

    A practical guide for a modern flat: 8–12 sockets in the living room, 6–8 per bedroom, 10–14 in the kitchen including appliances, and 4 at a desk. Fewer means extension leads, which are a risk in themselves.

    07

    Protective devices and what each one does

    Apartment electrical wiring has to protect against three different hazards, and each has its own device. A circuit breaker protects the cable from overload and short circuit. A residual-current device protects people from electric shock. A voltage relay protects appliances from supply surges.

    The most common misconception is confusing the first two: many people assume an ordinary breaker protects against shock. It does not — a breaker trips only when current exceeds its rating, and the current that kills a person is far below that. This is why a 30 mA RCD is mandatory on wet-zone circuits.

    A voltage relay is particularly worth having in Georgia, where supply instability in older districts is routine and a single serious surge can take out every appliance in the flat. It costs a fraction of a fridge and protects the lot.

    08

    Assembling the board properly

    The board should be logically grouped and sited somewhere accessible — not behind a wardrobe or in a loft. Every way needs a label that makes sense to you rather than to an electrician: “Kitchen — sockets”, not “L3”.

    Twenty per cent spare capacity is not optional. In five years you may want air conditioning, a water heater or an EV charger, and if there is no room in the board the whole board gets replaced.

    09

    What to require at handover

    • A board schedule showing which breaker feeds what
    • An insulation resistance test certificate
    • RCD test-button operation demonstrated in your presence
    • Photographs of every cable run before the walls were closed

    That last item is the most valuable in practice: when you drill into a wall five years from now, those photographs are what stop you cutting a live cable.

    10

    Frequently asked questions

    11

    What does rewiring cost?

    In Georgia, labour runs around 10–15 GEL per m², with materials adding up to another 15 depending on cable quality — roughly 25–30 GEL per m² in total. The work itself takes two to seven days depending on size.

    12

    Can parts of the old wiring be kept?

    Aluminium wiring should be replaced entirely — it becomes brittle and heats at the terminations. Copper wiring may stay if the cross-section is adequate and the insulation is sound, but that has to be confirmed by measurement.

    13

    What should I allow for smart home systems?

    The key points are a neutral conductor at every switch box and a dedicated circuit for the control module. Allowing for this at first fix costs almost nothing; retrofitting means opening walls.

    For an indicative cost use the renovation calculator, and see our renovation guide for how this fits the wider sequence.